Air Quality Sensor
Tough, accurate and low-cost. Prana Air's air quality analysers cover both particulate matter and a whole range of gases.Inside every air monitor, indoor or outdoor, you will find air quality sensors. They detect pollution in the air. Many types exist, and each has a job of its own. A pollution sensor is made to measure one thing. That could be particulate matter, carbon monoxide, ozone, sulphur dioxide or nitrogen dioxide. These sensors used to cost a lot. With better tech, they have become cheaper and cheaper. Air pollution sensors now have a big part to play. They help us understand and study problems in the environment, both large and small.
Carbon Dioxide (CO2) Sensor
- ✓ Range: Upto 10,000 PPM
- ✓ Accuracy: ± 200 ppm ± 2%
- ✓ Resolution: 100 PPM
- ✓ Type of Sensor: NDIR sensor
Carbon Monoxide (CO) Sensor
- ✓ Range: 500 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.1 PPM
- ✓ Response Time: < 30 seconds
Sulfur Dioxide SO2 Sensor
- ✓ Range: 50 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.01 PPM
- ✓ Response Time: < 15 seconds
Nitrogen Dioxide NO2 Sensor
- ✓ PM Range: Upto 2000 μg/m3
- ✓ Particle Size Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Hydrogen Sulfide H2S
- ✓ Range: Upto 10,000 PPM
- ✓ Accuracy: ± 200 ppm ± 2%
- ✓ Resolution: 100 PPM
- ✓ Type of Sensor: NDIR sensor
Ozone O3 Sensor
- ✓ Range: 500 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.1 PPM
- ✓ Response Time: < 30 seconds
Ammonia NH3 Sensor
- ✓ Range: 50 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.01 PPM
- ✓ Response Time: < 15 seconds
Chlorine Cl2 Sensor
- ✓ PM Range: Upto 2000 μg/m3
- ✓ Particle Size Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Indoor PM Sensor
- ✓ PM Range: Upto 2000 μg/m3
- ✓ Particle Size Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Outdoor PM Sensor
- ✓ PM Range: Upto 2000 μg/m3
- ✓ Particle Size Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Indoor PM Sensor
- ✓ PM Range: Upto 0-2000 μg/m3
- ✓ Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Outdoor Air Monitor
- ✓ PM Range: Upto 31,000 μg/m3
- ✓ Resolution: 0.3 μm
- ✓ Purpose: Outdoor Monitors
- ✓ Working Temp.: -20~70 °C
Carbon Dioxide (CO2) Sensor
- ✓ Range: Upto 10,000 PPM
- ✓ Accuracy: ± 200 ppm ± 2%
- ✓ Resolution: 100 PPM
- ✓ Type of Sensor: NDIR sensor
Carbon Monoxide (CO) Sensor
- ✓ Range: 500 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.1 PPM
- ✓ Response Time: < 30 seconds
Sulfur Dioxide SO2 Sensor
- ✓ Range: 50 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.01 PPM
- ✓ Response Time: < 15 seconds
Nitrogen Dioxide NO2 Sensor
- ✓ PM Range: Upto 2000 μg/m3
- ✓ Particle Size Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Hydrogen Sulfide H2S
- ✓ Range: Upto 10,000 PPM
- ✓ Accuracy: ± 200 ppm ± 2%
- ✓ Resolution: 100 PPM
- ✓ Type of Sensor: NDIR sensor
Ozone O3 Sensor
- ✓ Range: 500 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.1 PPM
- ✓ Response Time: < 30 seconds
Ammonia NH3 Sensor
- ✓ Range: 50 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.01 PPM
- ✓ Response Time: < 15 seconds
Chlorine Cl2 Sensor
- ✓ PM Range: Upto 2000 μg/m3
- ✓ Particle Size Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Reasons to Choose Prana Air Sensors
Prana Air air quality sensors are designed with finesse and precision. They serve safety monitoring in homes and in industry. Each modern sensor carries the latest tech for spotting what pollutes the air.
Structured Design
Prana Air sensors are ultra-thin and tiny. That means they fit into any kind of device or instrument. Handheld devices are a natural match for sensors this small. So is real-time outdoor monitoring.
Highly Receptive
Most of our gas sensors respond in under 15 seconds on average. They are robust and quick. So they are purpose-built for real-time monitoring, where results need to be both fast and exact.
RoHS Compliant
For electrical and electronic equipment, the Restriction of Hazardous Substances Directive (RoHS) applies, and our sensors meet it.
Sturdy-Built
Up to a decade of checking your air, without fuss: that is what these highly accurate air pollution sensors offer. Fit one in your instrument, and there is no need to think about it again.
Low-Carbon Sensors
A low power input (0 mW at 0 mV bias) is all our air quality analysers need. Energy is saved, the carbon footprint gets smaller, and you move one step closer to sustainability.

Individually Calibrated
Every device fitted with our sensors is calibrated on its own. That yields highly accurate readings, with errors kept to a minimum. It makes our sensors a safe bet when exact readings are what you need.
Prana Air Sensor Calibration
Prana Air Sensor Accuracy
PM2.5 correlation with high-end equipment

Talk to Us
Share your requirements with us, and our team will get back to you very soon.
Loading Form...
Trusted By