Air Quality Sensor
Prana Air's low-cost air quality analysers measure particulate matter and gases. Tough build, accurate readings.Whether a monitor works indoors or out in the open, it depends on air quality sensors. They sense pollution in the air. Sensors come in a range of types, each with its own job. A sensor is built to measure one certain thing. It might be particulate matter, carbon monoxide, ozone, sulphur dioxide or nitrogen dioxide. Once upon a time, sensors were out of reach for most budgets. Better tech has brought prices down, and they keep getting cheaper. Air pollution sensors now matter a great deal. They help us understand and study problems in the environment.
Carbon Dioxide (CO2) Sensor
- ✓ Range: Upto 10,000 PPM
- ✓ Accuracy: ± 200 ppm ± 2%
- ✓ Resolution: 100 PPM
- ✓ Type of Sensor: NDIR sensor
Carbon Monoxide (CO) Sensor
- ✓ Range: 500 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.1 PPM
- ✓ Response Time: < 30 seconds
Sulfur Dioxide SO2 Sensor
- ✓ Range: 50 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.01 PPM
- ✓ Response Time: < 15 seconds
Nitrogen Dioxide NO2 Sensor
- ✓ PM Range: Upto 2000 μg/m3
- ✓ Particle Size Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Hydrogen Sulfide H2S
- ✓ Range: Upto 10,000 PPM
- ✓ Accuracy: ± 200 ppm ± 2%
- ✓ Resolution: 100 PPM
- ✓ Type of Sensor: NDIR sensor
Ozone O3 Sensor
- ✓ Range: 500 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.1 PPM
- ✓ Response Time: < 30 seconds
Ammonia NH3 Sensor
- ✓ Range: 50 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.01 PPM
- ✓ Response Time: < 15 seconds
Chlorine Cl2 Sensor
- ✓ PM Range: Upto 2000 μg/m3
- ✓ Particle Size Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Indoor PM Sensor
- ✓ PM Range: Upto 2000 μg/m3
- ✓ Particle Size Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Outdoor PM Sensor
- ✓ PM Range: Upto 2000 μg/m3
- ✓ Particle Size Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Indoor PM Sensor
- ✓ PM Range: Upto 0-2000 μg/m3
- ✓ Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Outdoor Air Monitor
- ✓ PM Range: Upto 31,000 μg/m3
- ✓ Resolution: 0.3 μm
- ✓ Purpose: Outdoor Monitors
- ✓ Working Temp.: -20~70 °C
Carbon Dioxide (CO2) Sensor
- ✓ Range: Upto 10,000 PPM
- ✓ Accuracy: ± 200 ppm ± 2%
- ✓ Resolution: 100 PPM
- ✓ Type of Sensor: NDIR sensor
Carbon Monoxide (CO) Sensor
- ✓ Range: 500 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.1 PPM
- ✓ Response Time: < 30 seconds
Sulfur Dioxide SO2 Sensor
- ✓ Range: 50 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.01 PPM
- ✓ Response Time: < 15 seconds
Nitrogen Dioxide NO2 Sensor
- ✓ PM Range: Upto 2000 μg/m3
- ✓ Particle Size Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
Hydrogen Sulfide H2S
- ✓ Range: Upto 10,000 PPM
- ✓ Accuracy: ± 200 ppm ± 2%
- ✓ Resolution: 100 PPM
- ✓ Type of Sensor: NDIR sensor
Ozone O3 Sensor
- ✓ Range: 500 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.1 PPM
- ✓ Response Time: < 30 seconds
Ammonia NH3 Sensor
- ✓ Range: 50 PPM
- ✓ Power Consumption: 10 to 50 uW
- ✓ Resolution: 0.01 PPM
- ✓ Response Time: < 15 seconds
Chlorine Cl2 Sensor
- ✓ PM Range: Upto 2000 μg/m3
- ✓ Particle Size Resolution: 0.3 μm
- ✓ Purpose: Indoor Monitors
- ✓ Working Temp.: -20~70 °C
What Makes Prana Air Sensors Worth Choosing?
Finesse and precision go into every Prana Air air quality sensor, whether it is for home safety monitoring or industry. Modern and packed with the latest tech, our sensors detect what pollutes the air.
Structured Design
Thanks to an ultra-thin package and a tiny design, Prana Air sensors slot into any kind of device or instrument. They are a good fit for handheld devices and for real-time outdoor monitoring alike.
Highly Receptive
Most of our gas sensors have an average response time under 15 seconds. So they are robust and quick to respond. That makes them tailor-made for real-time monitoring, with faster and more exact results.
RoHS Compliant
RoHS? Box ticked. Our sensors follow the Restriction of Hazardous Substances Directive covering electrical and electronic equipment.
Sturdy-Built
Highly accurate and free of hassle, these air pollution sensors can watch over your air for up to a decade. Set them in your instrument once and put sensor worries out of mind.
Low-Carbon Sensors
Low power input (0 mW at 0 mV bias) is a big plus of our air quality analysers. They save energy and leave a smaller carbon footprint. They also take you one step closer to sustainability.

Individually Calibrated
Each device that houses our sensors is calibrated on its own. That gives highly accurate readings with errors kept to a minimum. It is what makes our sensors a reliable choice when precision counts.
Prana Air Sensor Calibration
How Accurate Our Sensors Are
PM2.5 matched against a high-end instrument

Get in Contact
Let us know what you are after and one of the team will be in touch very soon.
Loading Form...
Trusted By
Some of the industry's biggest organisations